Built tough, reliable and ready for action!

For whatever you face in a day, the Philips HeartStart MRx Defibrillator is built to be tough and ready for action. The HeartStart MRx is designed to meet stringent test requirements including spraying water, military helicopter vibration, mechanical shock, one-meter drop, electro-magnetic compatibility, and extreme environmental conditions (temperature, humidity and altitude).

In addition, the same MRx model that we ship to all EMS customers has passed an extensive battery of tests, performed by the US military, to achieve aeromedical air-worthiness certification. These military-level tests include: baseline performance and durability, electrical safety, vibration, electro-magnetic compatibility, climate, altitude, rapid decompression, explosive atmosphere, acceleration, and in-flight performance evaluations.

Although we show several options, the Philips HeartStart MRx Series Defibrillator can be configured in a variety of ways: 3- Lead ECG, 12-Lead ECG, SpO2, NiBP, etCO2, IBP and Temperature – pulse oximeter, 2 channels of invasive blood pressure and end tidal CO2

All configurations include the following features:

·         Manual defibrillation

·         AED mode

·         ECG arrhythmia detection

·         Automated testing

·         AC power module w/ power cord (M3539A)

·         One battery pack (M3538A), one metal bedrail hook (M3549A)

·         3-lead ECG cable (M1669A, M1673A)

·         Pad cable (M3508A)

·         Test load (M3725A)

·         One roll of paper

·         Carrying Case

·         CD with Instructions for Use

Please call 800.558.6270 for additional options.

All re-certified defibrillators come with a one year warranty.

We also carry Re-Certified Battery Chargers – please call 800.558.6270 for pricing and more information.

Remain in Compliance - Protect Yourself and Your Company from Liability:
Both the CAAS (Commission on Accreditation of Ambulance Services) and the FDA recommend a Preventative Maintenance Program for Defibrillators. Please ask about our Preventative Maintenance Programs.

Per Federal Law, all of the items listed on this webpage are prescription drugs and/or devices. Before your account can receive these items, we must have a completed Prescription Drug Authorization (PDA) Form on file signed by your Medical Director. Orders from individuals will not be accepted.

Product Specifications

Physical

  • Dimensions
    • Without external paddles: 12.4” W x 7.7” D x 11.7” H
    • With external paddles: 12.4” W x 7.7” D x 13.4” H
  • Weight: 13.2 lbs. (base unit with one battery, pads, and pads’ cable)

Environmental and physical requirements

  • Solids/Water Resistance: IP24
  • Temperature:
    • Operating: 32º - 113º F (0º - 45º C)
    • Storage: -4º - 158º F (-20º - 70º C)
  • Humidity:
    • Operating: 0% to 95% relative
  • Altitude
    • Operating: 0 to 15,000 ft.
    • Storage: 0 to 15,000 ft.
  • Mechanical Shock Bump: IEC 68-2-29
  • Free-fall: IEC 68-2-32
  • Vibration:
    • Operating: MIL STD 810E 514.4 Category 6 Helicopter, General Storage, UH60
    • Non-Operating: IEC 68-2-6 Swept Sine Vibration and IEC 68-2-64 Random Vibration
  • Safety: Meets EN 60601-1, UL 2601-1, CSA C22.2 No. 601-1

Display

  • Dimensions: 8.4’’ diagonal
  • Type: TFT color LCD
  • Resolution: 480 x 640 pixels (VGA)
  • Wave Viewing Time: 5 seconds (ECG)

Defibrillation

  • Waveform Truncated: Exponential Biphasic. Waveform parameters adjusted as a function of patient impedance.
  • Output Energy: Manual (selected): 1-10, 15, 20, 30, 50, 70, 100, 120, 150, 170, 200 Joules into a 50 Ohm load AED Mode (single energy output): 150 Joules into a 50 ohm load.
  • Charge Time: Less than 5 seconds to 200 Joules with a new, fully charged lithium ion battery at 25º C
  • Shock Delivery: Via multifunction defib electrode pads or paddles
  • Shock-to-Shock Cycle Time: Typically less than 20 seconds
  • Patient Impedance Range:
    • Minimum: 15 Ohm (internal defibrillation); 25 Ohm (external defibrillation)
    • Maximum: 180 Ohm
  • AED Mode: Shock advisory sensitivity and specificity meet AAMI DF-39 guidelines

Battery

  • Type: 6.3 Ah, 14.8 V, rechargeable lithium ion
  • Dimensions: 6.5" H x 3.8" W x 1.6" D
  • Weight: 1.6 lb.
  • Charge Time: Approximately 3 hours from fully depleted to 100%, 90 minutes from fully depleted to 80%
  • Capacity:
    • At least 5 hours of continuous 12-lead ECG, SpO2, and CO2 monitoring, with NBP every 15 minutes on one new, fully charged battery
    • At least 3.5 hours of continuous 12-lead ECG, SpO2, and CO2 monitoring, with NBP every 15 minutes and pacing at 180 ppm at 160 mA on one new, fully charged battery
  • Battery Indicators: Battery gauge on battery, capacity indicator on display; flashing RFU indicator, chirp, and ‘Low Battery’ message appears on display for low battery condition, when 10 minutes of monitoring time and 6 maximum energy discharges remain (with a new battery at room temperature, 25º C)

Strip chart recorder

  • Recorder:
    • Standard: 50 mm (paper width) thermal array printer
    • Optional: 75 mm (paper width) thermal array printer
  • Continuous ECG Strip: Prints primary ECG lead with event annotations and measurements in real-time or with 10-second delay
  • Auto Printing: Recorder can be configured to print marked events, charge, shock and alarms
  • Reports: Event Summary, 12-Lead, Operational Check, Configuration, Status Log, and Device Information
  • Paper Size:
    • 1.97” W x 100’ L
    • 2.95” W x 100’ L 

Data storage

  • Internal: 12 hours of continuous ECG waveforms and events, plus 50 12-lead ECG reports
     
  • Data Card: 12 hours of continuous ECG waveforms and events, plus 50 12-lead ECG reports, on a CompactFlash memory card

ECG and arrhythmia monitoring

  • Input: Up to 4 ECG waves displayed and up to 3 ECG waves print simultaneously. Lead I, II, or III obtained through 3-lead ECG cable and separate monitoring electrodes. With 5-lead cable, obtain leads I, II, III, aVR, aVL, aVF, or V. Pads ECG obtained through 2 multifunction defibrillation electrode pads.
  • Lead Fault: ‘Lead Off ’ message and dashed line displayed, if an electrode or lead wire becomes disconnected
  • Pads Fault: Dashed line displayed if a pad becomes disconnected.
  • Heart Rate Display: Digital readout on display 15 to 300 bpm, accuracy ±10%
  • Heart Rate/Arrhythmia Alarms: HR, Asystole,VFIB/VTACH,VTACH, extreme tachycardia, extreme bradycardia, PVC rate
  • ECG Size 2.5, 5,10, 20, 40 mm/mV, autogain

SpO2 pulse oximetry

  • Range: 0 to 100%
  • Resolution: 1%
  • Alarm Range:
    • Low Limit: 50 to 99% (Adult/Pediatric)
    • High Limit: 51 to 100% (Adult/Pediatric)
  • Alarm Delay: 10 seconds

Noninvasive Blood Pressure

  • Pressure Range:
    • Systolic: 40 to 260 mmHg
    • Diastolic: 20 to 200 mmHg
  • Initial Pressure:
    • Adult: 160 mmHg
    • Pediatric: 120 mmHg
  • Maximum Pressure: 280 mmHg
  • Alarm Range:
    • Systolic high limit: 30 - 270 (Adult), 35 - 180 (Pediatric)
    • Systolic low limit: 30 - 265 (Adult), 30 - 175 (Pediatric)
    • Diastolic high limit: 18 - 240 (Adult), 18 - 150 (Pediatric)
    • Diastolic low limit: 10 - 240 (Adult), 10 - 145 (Pediatric)

End-tidal CO2

  • Range: 0 to 99 mmHg
  • Resolution: 1 mmHg (0.1 kPa)
  • Sample Size: 50 ml per minute
  • Alarm Range:
    • Low Limit: 10 to 95 mmHg (Adult/Pediatric)
    • High Limit: 20 to 100 mmHg (Adult/Pediatric)

12-lead ECG

  • Input: 12-Lead cable: leads I, II, III, aVR, aVL, aVF,V/C1-V/C6
  • Display View: All 12-lead ECG waves display simultaneously
  • Strip Recorder: All 12-leads print on the strip chart printer in 3x4 format
  • Transmission: CompactFlash data card; Bluetooth® dial-up Internet connection, Bluetooth® FTP

CPR feedback and measurement

  • Compression Depth: Target: -1.50 to -2.00 in. (-38 to -51 mm)
  • Compression Rate: Target: 90 to 120 cpm
  • Ventilation Volume: Graphic indicator: empty, 1/3-full, 2/3-full, full
  • Ventilation Rate:
    • Target for breaths delivered before 60 seconds since last compression: 6 to 16 vpm
    • Target for breaths delivered beyond 60 seconds since last compression: 9 to 16 vpm

Noninvasive pacing

  • Waveform: Monophasic Truncated Exponential
  • Current Pulse AmplitudeL: 10 mA to 160 mA (5 mA resolution); accuracy 10 mA to 50 mA ± 5 mA, 50 mA - 160 m A ± 10%
  • Pulse Width: 40 ms with ± 10% accuracy
  • Rate: 30 ppm to 180 ppm (10 ppm increments); accuracy ± 1.5%
  • Modes: Demand or Fixed Rate
  • Refractory Period: 340 msec (30 to 80 ppm); 240 msec (90 to 180 ppm)